写一段SMART 200的程序;版本7.5
1.两种控制模式,手动状态下禁用自动模式;自动状态下禁用手动模式2.运行状态,启动和停止有对应的显示状态3.故障反馈,有故障触发,需要停止电机启动和停止,禁止输出
4.故障信号需复位
5.梯形图格式
START:
// 初始化各项参数
SET manualMode = 1
SET autoMode = 0
SET motorStatus = "STOP"
SET faultStatus = "NO FAULT"
SET faultSignal = 0
// 显示启动信息
DISPLAY "SMART 200 Version 7.5"
DISPLAY "System starting up..."
// 检测输入
IF inputMode = "AUTO" THEN
SET manualMode = 0
SET autoMode = 1
ELSEIF inputMode = "MANUAL" THEN
SET autoMode = 0
ELSE
// 输入错误,触发故障
SET faultStatus = "INVALID INPUT"
SET faultSignal = 1
GOTO FAULT
ENDIF
// 运行状态
WHILE 1 DO
IF manualMode = 1 THEN
// 手动模式下禁用自动模式
IF autoMode = 1 THEN
SET autoMode = 0
ENDIF
// 手动模式操作
IF inputButton = "START" THEN
SET motorStatus = "RUNNING"
ELSEIF inputButton = "STOP" THEN
SET motorStatus = "STOP"
ENDIF
ELSEIF autoMode = 1 THEN
// 自动模式下禁用手动模式
IF manualMode = 1 THEN
SET manualMode = 0
ENDIF
// 自动模式操作
SET motorStatus = "RUNNING"
WAIT timeInterval
ENDIF
// 故障反馈
IF faultSignal = 1 THEN
GOTO FAULT
ENDIF
// 显示状态信息
DISPLAY "Motor status: " + motorStatus
// 检测输入
IF inputMode = "AUTO" THEN
SET manualMode = 0
SET autoMode = 1
ELSEIF inputMode = "MANUAL" THEN
SET autoMode = 0
ENDIF
ENDWHILE
GOTO START
FAULT:
// 停止电机启动和停止
SET motorStatus = "STOP"
// 禁止输出
SET outputStatus = "DISABLED"
// 显示故障信息
DISPLAY "FAULT: " + faultStatus
// 复位故障信号
SET faultSignal = 0
GOTO START
END.